Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13635107

- Product Categories
- Friendly Links
- home > Supply > Jess Tel drain valve, steam traps, level electrodes, controllers, check valves, boiler-line monitoring system, steam flow meter
Jess Tel drain valve, steam traps, level electrodes, controllers, check valves, boiler-line monitoring system, steam flow meter
Information Name: | Jess Tel drain valve, steam traps, level electrodes, controllers, check valves, boiler-line monitoring system, steam flow meter |
Published: | 2014-12-26 |
Validity: | 100000000 |
Specifications: | BK45 / MK45 / BK15 / UNA45 |
Quantity: | 10000.00 |
Price Description: | |
Detailed Product Description: | MK bellows thermostatic steam traps are very sensitive response characteristics ● Features ● High pressure was unaffected function ● auto exhaust (exhaust heat for steam systems) ● Mounting position any (vertical or horizontal lines) ● Even under low pressure with a high fever and drainage capability ● tandem seat (double sealing) ● Built-in check valve ● Stainless steel trim (Hastelloy corrugated diaphragm) ● U type too cold diaphragm; condensed water can be retained in order to take full advantage of partial condensation sensible heat of water. ● and PT100 temperature probe thermostatic bellows choose one of three forms, standard bellows "N" for the immediate discharge of condensate, in fact, no condensate accumulation, open valve temperature below the saturation temperature of about 10K (℃ ). 2, micro subcooling membrane cartridge "H" for condensate removal, no condensate accumulation, discharge temperature below the saturation temperature 5K (℃). 3, the membrane cartridge subcooling "U" for the use of the sensible heat of the condensate, which has accumulated condensate consciousness, in order to saving (by accumulation of condensed water in part of the use therein and to partially reduce the sensible heat of flash steam). Open valve temperature lower than the saturation temperature of about 30K (℃). Uses Model Application MK45-1 MK35 / 311) series seat (double sealing) for low condensate flow, steam heating, steam pipes and drainage, exhaust MK45-2 MK35 / 321) single seat for medium condensate flow steam heating, heat exchangers hydrophobic vent MK25 / 21) MK25 / 2 S1) MK35 / 2 S1) MK35 / 2 S31) single seat for large condensate flow, heat hydrophobic MK36 / 511) MK36 / 521) tandem seat (double seal) - with a flat gasket for low condensate flow, steam heating, steam pipes and drainage, exhaust, break vacuum MK45 A-1 MK45 A-2 for small and large flow Hydrophobic flow, steam heating, steam pipeline drainage, exhaust 1) can be used to break the vacuum. Exhaust bellows traps used for exhaust bellows thermostatic steam trap MK series can also be used for venting. Application of thermostatic steam trap steam pipelines and heat exchangers can be used as discharge of air and non-condensable gas and steam / air mixture. Sometimes may require special capsule model. Pressure / temperature rating model pressure levels PN △ PMX [bar] Materials maximum pressure / temperature rating EN ASTM PMA / TMA PMA / TMA MK35 / 31 PN25 21 P250 GH1) A1051) 18.6bar / 225 ℃ 14.4bar / 400 ℃ MK35 / 32 PN25 21 P250 GH1) A1051) 18.6bar / 225 ℃ 14.4bar / 400 ℃ MK45-1 PN40 22 P250 GH1) A1051) 28.4bar / 250 ℃ 23.1bar / 400 ℃ MK45-2 PN40 22 P250 GH1) A1051) 28.4bar / 250 ℃ 23.1bar / 400 ℃ MK35 / 2 S DN25 PN40 22 P250 GH A1053) 28.4bar / 250 ℃ 23.1bar / 400 ℃ MK35 / 2 S3 DN25 PN40 22 P250 GH A1053) 28.4bar / 250 ℃ 23.1bar / 400 ℃ MK25 / 2 DN40 / 50 PN40 22 P250 GH A1053) 28.4bar / 250 ℃ 23.1bar / 400 ℃ MK25 / 2 S DN40 / 50 PN40 22 P250 GH2) A1052) 3) 28.4bar / 250 ℃ 23.1bar / 400 ℃ MK36 / 51 , MK36 / 52 - 22 1.43014) A182 F304 32bar / 240 ℃ 32bar / 240 ℃ MK 45 A-1 PN40 22 1.44041) A182 F316L1) 29.3bar / 200 ℃ 24bar / 400 ℃ MK 45 A-2 PN40 22 1.44041) A182 F316L1 ) 29.3bar / 200 ℃ 24bar / 400 ℃ 1) All materials comply with the requirements of DIN and ANTM. 2) MK25 / 2S DN40 / 50: shell cover material steel GS-C25 (corresponding to ASTM: A216.WCB). 3) Physical and chemical properties in accordance with DIN standard, ASTM closest peer label for reference. 4) closest peer DIN standard for reference purposes only. Jess Tel MK bellows thermostatic steam trap trap Product Overview:, the basic role is to exhaust steam system condensate, air and carbon dioxide as soon as possible; at the same time maximizing automatically prevent steam leakage. Many traps varieties, each with different performance. Traps choice, should first elect their identity can satisfy the optimum operating steam heating equipment, before considering other objective conditions, so you need to select the trap is the correct and effective. Jess Tel BK supply bimetallic thermostatic trap BK series features: ● Spool strong and solid for the most humble workplace, water hammer, freeze-resistant; ● for saturated steam, the operating characteristic curve tracking saturation; ● There used to superheated steam at a stable operating temperature, can achieve satisfactory results emissions; ● automatic exhaust; ● vertically, horizontally installed at any angle; ● both stepped orifice valve function; ● All stainless steel internal parts; ● available Online repair; ● metal seat covers, to ensure an effective seal between the metal body and is the core; ● maximum differential pressure of up to 250barg. ● Optional accessories: BK45 condensate can be mounted monitors and PT100 temperature probe. This trap works jointly operated by the opening and closing of stainless steel bimetal temperature sensors and stepped valve port. Device is enabled and when condensed water and air, double metal stainless steel sheet is flat, working to try to make the valve opening pressure, the valve is fully open. Figure 1 when the condensate temperature rises, the bimetal deflection starts and pulled toward the stepped valve port closed (thermostatic effect), and is formed by a flash operating pressure (secondary evaporation) in a stepped port pressure (dynamic action) and its role opposite direction Static heat. The size of the valve hole in the equilibrium is dependent on temperature and pressure of the closing force and the opening force related both. Figure 2 when the temperature is raised to just below the saturation point (boiling point), the deformation of the bimetal reaches such an extent such that a stepped valve port is almost completely closed. The result is filled with the entire stepped end flash valve chamber, the valve chamber stepped pressure drop and collapse, the valve port is closed. There bimetal deflection temperature resulting in insufficient to produce enough over the entire pressure range to compete in a stepped valve opening direction of the valve force. Therefore the bimetal made of a stack, it can be like a spring, having stretch characteristics vary in a stepped valve port, due to the working pressure dependent force generated. Static heat balance and spring characteristics, so the temperature remains open and close just below the saturation temperature in the range of about a few degrees. Also known as the "action feature tracking saturation curve." Open valve during open higher effect is generated by thermal power trap in the open away from the valve seat both instantaneous, allowing condensate curve has to jump. Heating process for open-loop control purposes. The following saturated steam pipeline drainage ● ● ● superheated steam lines steam heating can also be used for hot exhaust. ● Dual exhaust metal trap for thermostatic bimetallic corrosion resistant stainless steel exhaust valve of BK series thermostatic steam traps can also be used to exhaust ● Applications thermostatic steam trap can be used for pipelines and heat exchangers auto exhaust emissions of non-condensable gases and steam / air mixture, you may need to make special adjustments. Materials, pressure / temperature rating model pressure levels PN △ PMX [bar] Materials maximum pressure / temperature rating EN ASTM PMA / TMA PMA / TMA BK451) PN40 22 P250 GH2) A1052) 28.4bar / 250 ℃ 23.1bar / 400 ℃ BK15 DN40 / 50 PN40 22 P250 GH2) A1052) 28.4bar / 250 ℃ 23.1bar / 400 ℃ BK465) PN40 32 1.5415 A182 F13) 30.2bar / 300 ℃ 28.4bar / 450 ℃ BK37 PN63 / 100 45 1.5415 A182 F13) 100bar / 350 ℃ 34.3bar / 530 ℃ BK27N DN40 / 50 PN63 45 1.5415 A182 F13) 47.6bar / 300 ℃ 25.8bar / 500 ℃ BK28 PN100 / 160 85 1.5415 A182 F13) 100bar / 350 ℃ 34.3bar / 530 ℃ BK29 PN160 110 1.7335 A182 F12 146.1 bar / 350 ℃ 44.5bar / 540 ℃ BK212 PN630 250 1.7383 A182 F222) 447.5bar / 500 ℃ 4) 163.0bar / 580 ℃ 4) BK212-F91 - 250 1.4901 / F91 - 932.9bar / 500 ℃ 348.4bar / 600 ℃ BK37 -ASME Class 400/600 45 - A182 F12 67.0bar / 450 ℃ 42.0bar / 500 ℃ BK28 ASME Class 600 85 - A182 F12 80.4bar / 350 ℃ 50.6bar / 500 ℃ BK29 ASME Class 900 110 - A182 F12 120.7bar / 350 ℃ 43.6bar / 540 ℃ BK212 ASME Class 2500 250 - A182 F12 231.7bar / 500 ℃ 63.0bar / 593 ℃ 1) provides: BK45U (condensate drain subcooling 30K) 2) material meets the EN and ASTM requirements. 3) Physical and chemical properties comply with EN standard ASTM peer grades for reference only. 4) to take special bolts and nuts 5) BK46 BK16 type connection structure instead length DN15 1/2 "DN20 3/4" DN25 1 "DN40 1-1 / 2" DN50 2 "BK45 (DN12 ~ 25) BK15 (DN40 50) flange EN PN40 150 150 160 230 230 flanges ASME 150 150 150 160 230 230 flanges ASME 300 150 150 160 230 230 thread 959595130230 socket welding (SW) 95 95 95 130 230 Butt ( BW) 200 200 200 250 250 BK46 flange EN PN40 150 150 160 - - Flanges ASME 300 150 150 160 - - Thread 95 95 95 - - Socket Weld (SW) 95 95 95 - - BK27N (DN40,50) Act Lan EN PN40 - - - 230 230 flange EN PN63 - - - 260 300 flanges ASME 400/600 - - - 241 292 socket weld (SW) - - - 180 180 butt (BW) - - - 180 180 BK37 / BK28 flange EN PN63 / 100 210 230 230 - - socket weld (SW) 160 160 160 - - Butt (BW) 160 160 160 - - BK29 flange EN PN160 210 230 230 - - socket weld (SW) 160 160 160 - - Butt (BW) 160 160 160 - - BK212 Butt (BW) 330 330 330 - - socket weld (SW) 330 330 330 - - BK212-F91 butt (BW) 330 330 330 BK37- Flange ASME ASME400 / 600 230 230 230 - - socket welding (SW) 160 160 160 Butt (BW) 160 160 160 - - BK28-ASME flanges ASME400 / 600 230 230 230 - - socket welding (SW) 160 160,160 Butt (BW) 160 160 160 - - BK29-ASME flanges ASME900 / 1500 230 230 254 - - socket weld (SW) 200 200 200 butt (BW) 200 200 200 - - BK212-ASME socket weld (SW) 330 330 330 butt (BW) 330 330 330 displacement curves trap:, the basic role is to condense the steam system in water, air and carbon dioxide emissions as soon as possible; at the same time maximizing automatically prevent steam leakage. Many traps varieties, each with different performance. Traps choice, should first elect their identity can satisfy the optimum operating steam heating equipment, before considering other objective conditions, so you need to select the trap is the correct and effective. Jay UNA float trap PN16-PN160 UNA series belong to float steam traps, condensate flow advantage for sudden changes and substantial changes and circumstances under pressure fluctuations of condensate discharge unaffected. UNA series features: from back pressure and condensate temperature; scroll ball mouth, less friction, movement of small moments, small volume compared with the same type; scroll ball reduces the operating force, control component is very small; as always maintain a water seal, No live steam loss; even during strong fluctuations load and stress does not appear condensate accumulating; especially suitable for the control of the steam side heat exchanger; not dirty influence; dual control (Duplex) type automatic hot hydrostatic exhaust; single control (Simplex) type suitable air condensate, chemical distillate and distillate excluded; online repair; can be used in a vacuum system (single control). UNA25-PK trap pump PN40, DN40 automatic pump trap is a trap, combining a mechanical pump and check valve integration (triple) in. In normal conditions, it works to trap mode, condensate can drain away; when the "stagnation", it will work in the pump mode, high voltage power steam condensate will drain away. It can be said in any trap pump equipment load, can ensure that no accumulation of condensate in the heat exchanger, also no maintenance, greatly improving the reliability of equipment operation, quality and cost-effectiveness. Condensate pump trap steam trap except basic functions, but also be able to work in the case of low vapor pressure or high back pressure to upgrade and discharged through the power of steam condensate. The control means comprises a float, rolling ball, the guide hole, and a switching lever means controls the exhaust gas outlet of the motive steam inlet valve block. UNA25-PK features include an inlet valve, outlet valve, power steam inlet and exhaust outlet. Supply Jess Jess Tel Tel UNA float trap UNA float trap trap Product Overview:, the basic role is to condense the steam system in water, air and carbon dioxide emissions as soon as possible; at the same time maximizing automatically prevent steam The leakage. Many traps varieties, each with different performance. Traps choice, should first elect their identity can satisfy the optimum operating steam heating equipment, before considering other objective conditions, so you need to select the trap is the correct and effective |
Admin>>>
You are the 7846 visitor
Copyright © GuangDong ICP No. 10089450, Jess Alice Gao International Development Group Tel China distributor All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 7846 visitor
Copyright © GuangDong ICP No. 10089450, Jess Alice Gao International Development Group Tel China distributor All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility